• Measures level within 0.25" (6 mm) from the end of the tip-sensitive transducer
• 10 amp DPDT gold flash or 5 amp DPDT hermetically-sealed relay
• Field selectable failsafe
• FM, CSA and ATEX approval for hazardous locations
• No calibration required
• 316 stainless steel transducer
• Pulsed electronics for excellent performance in difficult process conditions and superior immunity from sources of electromagnetic noise
• Advanced transducer design provides reliable operation by draining viscous liquids and ignoring foam in turbulent applications
• Suitable for SIL (Safety Integrity Level) 2 loops (FMEDA analysis data available)
• Extremely compact unit is easily installed in areas where access space is limited
• No calibration or configuration necessary
• 1 amp SPDT relay output (940), 8/16 mA current shift output (941)
• Patent pending technology provides unsurpassed reliability and testing of electronics, transducer, piezoelectric crystals, and electromagnetic noise
• Adjustable time delay for turbulent aerated liquids
• Tip-sensitive transducer measures level within 1/4" of the vessel bottom
• Pulsed signal technology provides superior performance in difficult process conditions
• AS-i output reduces cabling costs and simplifies installation.
• No calibration
• Loop current or relay output
• Advanced diagnostics: sensor, electronics and electrical noise interference
• LED indication for alarm status and error
• Pushbuttons for manual testing of output
• Metal and plastic sensors
• Adjustable time delay for turbulent aerated liquids
• Pulsed signal technology
• Extensive FM, CSA and ATEX explosion proof and intrinsically safe approvals
• Suitable for Safety Integrity Level (SIL) 2 loops
• Temperature compensated to provide repeatable alarm under varying process temperatures
• Continuous diagnostics detect sensor fault
• Non-linear mA output signal can be used for trending, diagnostics and repeatable flow/level indication
• Detects minimum flow or presence / absence of flow
• Easy / fast calibration
• Excellent low flow sensitivity
• LEDs provide visual flow indication
• 24 VDC input power
• mA output signal for diagnostics and repeatable flow/level indication
• Adjustable set point and time delay
• SPDT Alarm relay
Ультразвуковому расходомеру «FLUXUS» присвоен Знак качества
Расходомер ультразвуковой «FLUXUS» модель ADMF601 аттестован на Знак качества по результатам экспертной оценки функциональных и метрологических характеристик
Присвоение Знака качества 2011
«Знак качества» выставки «MetrolExpo-2011» в конкурсной программе «За единство измерений» также присвоен следующим приборам:Отчеты о проведении испытаний FLUXUS ADM F601
Получены новые отчеты о проведении испытаний портативного ультразвукового расходомера FLUXUS ADM F601 с накладными датчиками от «Сургутской ГРЭС-2» филиала ОАО «ОГК-4», ОАО «КНПЗ», ЗАО «ТМ-Сервис».